Capabilities

Pressure Sensors


High Proof Pressure
5 to 200 times overload pressure (range dependent) without affecting transducers performance. This includes overload pressures in “Both Directions” for differential pressure sensors.
Pressure Ranges
Ranges from 1 PSI Full Scale, to 60,000 PSI Full Scale. (Absolute, Gage, Sealed Gage, Differential)
Temperature Extremes
Very High 1000ºF (538ºC) Continuous operation. Cryogenic –320ºF (-196ºC) Continuous operation.
Simultaneous Static and Dynamic Pressure Measurements
Ability to measure steady state pressure, and dynamic pressure with the same sensor.


Bridge Resistance
1,000 ohms typical. Custom requests from 350 ohms, through 15,000 ohms, is possible.
High Vibration
100g Peak, Sine 10 to 5,000 Hz
Shunt Calibration
Special option available upon request.

Completed Pressure Transducers


Transducer Outputs
Un-Amplified:
100mV typical Full Scale (others from 30mV to 300mV).
Amplified:
Standard options: 0-5 VDC, 0.5-5 VDC, 0-10 VDC, 4-20 mA
(Other outputs available upon request).
Special Amplified:
Potentiometer Replacement, LVDT or Variable Reluctance Replacement.
Sensor Physical Shape/Configuration
Almost any configuration your application requires, including pressure connections and electrical connections.
Submersible Transducers/Transmitters
To depths of 1100 ft. of water.

Pressure Switches
Single or multiple switched outputs all in one units. Used where high vibration, hostile environments and where accurate set point settings are required.
Dual and Triple redundant sensor designs for extreme reliability applications
Gauge pressure measurements within a Hermetically Sealed transducer